Remove the set_false_path, set_clock_group-asynchronous, or set_max_delay -datapath_only constraints between the synchronous clocks. If the clocks are truly asynchronous, add an asynchronous clock constraint and implement proper synchronization circuitry for the asynchronous clock domain crossing. To determine whether a clock domain crossing is synchronous or asynchronous, use the clock interaction report.