Your can choose to enable I/O data capture by selecting the associated check box. When this is enabled, the following three log files are created upon simulation of the system:
-
/<proj_location>/<proj_name>/<proj_name>.sim/sim_1/behav/<simulator_name>/<component
name>_stream_in.log
- This contains the
s_axisand input user metadata interfaces along with a timestamp. - The format of this file is:
tready,tvalid,tlast,tdata,tkeep,metadata_valid,metadataandtimestamp(tab separated values).
- This contains the
-
/<proj_location>/<proj_name>/<proj_name>.sim/sim_1/behav/<simulator_name>/<component
name>_stream_out.log
- This contains the m_axis and output user metadata interfaces along with a timestamp.
- The format of this file is:
tready,tvalid,tlast,tdata,tkeep,metadata_valid,metadataandtimestamp(tab separated values).
-
/<proj_location>/<proj_name>/<proj_name>.sim/sim_1/behav/<simulator_name>/<component
name>_control_if.log
- This contains the AXI4-Lite interface along with a timestamp.
- The format of this file is:
s_axi_awaddr,s_axi_awvalid,s_axi_awready,s_axi_wdata,s_axi_wstrb,s_axi_wvalid,s_axi_wready,s_axi_bresp,s_axi_bvalid,s_axi_bready,s_axi_araddr,s_axi_arvalid,s_axi_arready,s_axi_rdata,s_axi_rresp,s_axi_rvalid,s_axi_rreadyandtimestamp(tab separated values).