Step 2: Create an IP Integrator Design - Step 2: Create an IP Integrator Design - 2024.2 English - XD131

Programming an Embedded MicroBlaze Processor (XD131)

Document ID
XD131
Release Date
2024-11-20
Version
2024.2 English
  1. From Flow Navigator, under IP integrator, select Create Block Design.

  2. Specify the IP subsystem design name. For this step, you can use mb_subsystem as the Design name. Leave the Directory field set to its default value of <Local to Project>. Leave the Specify source set drop-down list set to its default value of Design Sources.

  3. Click OK in the Create Block Design dialog box, shown in the following figure.

    ../../_images/image1-1.png

  4. In the IP integrator diagram area, right-click and select Add IP.

    The IP integrator Catalog opens. Alternatively, you can also select the Add IP icon in the middle of the canvas.

    ../../_images/image2-1.png

  5. Type mig in the Search field to find the MIG core, then select Memory Interface Generator (MIG 7 Series), and press Enter.

    ../../_images/image3-1.png

    The Designer Assistance link becomes active in the block design banner.

  6. Click Run Block Automation.

    ../../_images/image4-1.png

    The Run Block Automation dialog box opens.

    ../../_images/image5-1.png

  7. Click OK. This instantiates the MIG core and connects the I/O interfaces to the I/O interfaces for the DDR memory on the SP701 board.

    ../../_images/image6-1.png

  8. Right-click anywhere in the block design canvas, and select Add IP. The IP catalog opens.

  9. In the Search field, type micr to find the MicroBlaze IP, then select MicroBlaze, and press Enter.

    Note: If not displayed by default, the IP Details window can be displayed by clicking CTRL+Q on the keyboard while searching for IP.

    ../../_images/image7-1.png ../../_images/image8-1.png