The Report section of the Options tab of the Report Timing Summary dialog box includes:

Path delay type
Sets the type of analysis to be run. For synthesized designs, only max delay analysis (setup/recovery) is performed by default. For implemented design, both min and max delay analysis (setup/hold, recover/removal) are performed by default. To run min delay analysis only (hold and removal), select delay type min.

Equivalent Tcl option: -delay_type

Report unconstrained paths
Generates information on paths that do not have timing requirements. This option is checked by default in the Vivado IDE, but is not turned on by default in the equivalent Tcl command report_timing_summary.

Equivalent Tcl option: -report_unconstrained

Report datasheet

Generates the design datasheet as defined in Report Datasheet, in this chapter.

Equivalent Tcl option: -datasheet