Important: You must perform the steps in this section
to match addresses for the design because Design Automation sets the addresses and
address size. These steps ensure compatibility with existing software.
- In a text editor, open the MHS file and select Address Editor in the block design.
- For each AXI slave or LMB block RAM in the MHS, obtain:
-
PARAMETER C_BASEADDR -
PARAMETER C_HIGHADDR
-
- Enter the
C_BASEADDRvalue under the Offset Address for the AXI slave or LMB block RAM. - Ensure the
C_HIGHADDRmatches the High Address column for the AXI slave or LMB block RAM. If there is a mismatch, adjust the Range column for the AXI Slave or LMB block RAM to match theC_HIGHADDR.If there are multiple AXI masters connected to an AXI slave, be sure to change the address on the multiple AXI masters for the Offset Address. For example,
microblaze_0/Dataandmicroblaze_0/Instruction.