TIMING-34: Bus Skew Constraint with Unrealistic Value - 2023.1 English

Vivado Design Suite User Guide: Design Analysis and Closure Techniques (UG906)

Document ID
UG906
Release Date
2023-05-16
Version
2023.1 English

There is a bus skew constraint with an unrealistic value (less than the minimum of half a source and destination clock period) or a <1 ns requirement (see constraint position <position> in the timing constraint window in Vivado IDE). Setting an aggressive value results in increased runtime. The first endpoint covered by the constraint is <object>.