AXI4-Lite Interfaces - 2023.1 English

H.264/H.265 Video Codec Unit v1.2 Solutions LogiCORE IP Product Guide (PG252)

Document ID
PG252
Release Date
2023-05-16
Version
2023.1 English

To verify that the interface is functional, try reading from a register that does not have all 0s as its default value. Output s_axi_arready asserts when the read address is valid, and output s_axi_rvalid asserts when the read data/response is valid. If the interface is unresponsive, ensure that the following conditions are met:

  • The s_axi_aclk and aclk inputs are connected and toggling.
  • The interface is not being held in reset, and s_axi_areset is an active-Low reset.
  • The interface is enabled, and s_axi_aclken is active-High (if used).
  • The main core clocks are toggling and that the enables are also asserted.