This function is used to stop NPI scan from user application. Primarily this function sends an IPI request to PLM to invoke SEM NPI StopScan, waits for PLM to process the request and reads the response message.
Prototype
XStatus XSem_CmdNpiStopScan(XIpiPsu *IpiInst, XSemIpiResp *Resp);
Parameters
The following table lists the XSem_CmdNpiStopScan
function arguments.
Type | Member | Description |
---|---|---|
XIpiPsu * | IpiInst | Pointer to IPI driver instance |
XSemIpiResp
* |
Resp |
Structure Pointer of IPI response
|
Returns
This API returns the success or failure.- XST_FAILURE: On NPI stop scan failure
- XST_SUCCESS: On NPI stop scan success