If you are targeting the VCU118 or KCU116, follow these instructions. UltraScale device instructions are further on in this section.

First, reconfigure the “upper” shifter location.

  1. Select Program device on the green banner (or right-click on the target device and select Program device). Navigate to the Bitstreams/inst_shift folder to select shift_left_upper_partial.bit, then click Program to program the device. The upper shift portion is now shifting left, while the lower portion is still shifting right. DONE has also returned high (on).

    In order to transition to counter functions, the first-order reconfig_counters RM must first be loaded. Loading any second-order count_up or count_down partial bitstreams at this point would not function properly, as these functions would not connect to the top-level static design.

  2. Select Program device on the green banner again. Navigate to the Bitstreams/inst_RP folder to select inst_RP_count_up_up_recombined_partial.bit, then click Program to program the device. The two sections of LEDs are now counting up.

    Now that the reconfig_counters first-order function is established, Reconfigurable Partitions below that hierarchy can be partially reconfigured.

  3. Select Program device on the green banner one last time. Navigate to the Bitstreams/inst_count folder to select count_down_lower_partial.bit, then click OK to program the device. The upper shift portion is still counting up, while the lower portion is now counting down.

    This concludes the lab instructions for UltraScale+ devices.