TIMING-7: No Common Node Between Related Clocks - 2021.1 English

Vivado Design Suite User Guide: Design Analysis and Closure Techniques (UG906)

Document ID
UG906
Release Date
2021-06-30
Version
2021.1 English

The clocks <CLOCK_NAME1> and <CLOCK_NAME2> are related (timed together) but they have no common node. The design could fail in hardware. To find a timing path between these clocks, run the following command: report_timing -from [get_clocks <CLOCK_NAME1>] -to [get_clocks <CLOCK_NAME2>].