Interactive Physical Optimization Command Reference - 2021.1 English

Vivado Design Suite User Guide: Implementation (UG904)

Document ID
UG904
Release Date
2021-08-30
Version
2021.1 English

The interactive physical optimization commands, along with corresponding options, are described below.

write_iphys_opt_tcl

This command writes a file containing the iphys_opt_design Tcl commands corresponding to the physical optimizations performed in the current design.

Syntax:

write_iphys_opt_tcl [-place] [-quiet] [-verbose] <output file>

The -place option directs the command to include placement information with the iphys_opt_tcl commands. Use this option when you intend to apply placement with netlist changes during iphys_opt_design command replay.

The write_iphys_opt_tcl command can be used any time after phys_opt_design has been run.

read_iphys_opt_tcl

This command reads a file containing the iphys_opt_design Tcl commands corresponding to the physical optimizations performed in a previous run.

Syntax:

read_iphys_opt_tcl	[-fanout_opt] [-critical_cell_opt] [-placement_opt] [-rewire] [-dsp_register_opt] [-bram_register_opt]
[-uram_register_opt][-shift_register_opt] [-critical_pin_opt] [-insert_negative_edge_ffs] [-slr_crossing_opt]
[-include_skipped_optimizations] [-quiet] [-verbose] <input file>
The read_iphys_opt_design command has many of the same options as phys_opt_design to limit the scope of replayed optimizations to only those specified. These options include:
  • -fanout_opt
  • -critical_cell_opt
  • -placement_opt
  • -rewire
  • -dsp_register_opt
  • -bram_register_opt
  • -uram_register_opt
  • -shift_register_opt
  • -insert_negative_edge_ffs
  • -slr_crossing_opt
  • -critical_pin_opt

Apply the skipped optimizations that are defined in the input Tcl script, as well as the standard optimizations. These are optimizations identified by phys_opt_design that are skipped because suitable locations for optimized logic cannot be found. When this option is specified, the iphys_opt_design command will attempt to use the included skipped optimizations in the pre-placement netlist.

iphys_opt_design

The iphys_opt_design command is a low-level Tcl command that performs a physical optimization. All default phys_opt_design optimizations can be performed using iphys_opt_design. Although it is possible to modify iphys_opt_design commands, and even to create them from scratch, you would typically write them to a script and replay them in a separate run.

Syntax

iphys_opt_design	[-fanout_opt] [-critical_cell_opt] [-placement_opt] [-rewire] [-net <arg>] -cluster <args> -place_cell <args> [-place]
[-dsp_register_opt] [-bram_register_opt] [-uram_register_opt] [-shift_register_opt] [-slr_crossing_opt] [-cell <arg>]
[-packing][-unpacking][-port <arg>] [-critical_pin_opt] [-skipped_optimization][-insert_negative_edge_ffs]
[-quiet] [-verbose]