Upgrade configurable IPIntegrator cell(s) to later version

Syntax

upgrade_bd_cells [‑latest <arg>] [‑quiet] [‑verbose] <objects>...

Returns

List of IPIntegrator cell names those were upgraded, "" if failed.

Usage

Name Description
[-latest] Upgrade the IPIntegrator block to the latest version
[-quiet] Ignore command errors
[-verbose] Suspend message limits during command execution
<objects> IPIntegrator cells to be upgraded

Categories

IPIntegrator

Description

Upgrade IP integrator cells to the latest version available in the IP integrator catalog.

This command lets you update IP integrator subsystem designs from an earlier release to use the IP cores from the latest catalog.

This command returns the list of IP integrator cells that were upgraded, or returns an error if it fails.

Arguments

-latest - (Optional) Upgrade the specified cells to the latest available version from the IP catalog. This option is the default, and is not required.

-quiet - (Optional) Execute the command quietly, returning no messages from the command. The command also returns TCL_OK regardless of any errors encountered during execution.
Note: Any errors encountered on the command-line, while launching the command, will be returned. Only errors occurring inside the command will be trapped.
-verbose - (Optional) Temporarily override any message limits and return all messages from this command.
Note: Message limits can be defined with the set_msg_config command.

<objects> - The IP integrator cells to upgrade to the latest version. These objects must be specified using the get_bd_cells command. Objects cannot be referenced by name.

Example

The following example upgrades the specified cells to the latest version available in the IP integrator catalog:
upgrade_bd_cells [get_bd_cells {vidOut1 cmpy_1 newMod1}]  
INFO: [BD 41-1162] The cell '/vidOut1' is already at its latest version.  
INFO: [BD 41-1162] The cell '/cmpy_1' is already at its latest version.  
WARNING: [BD 41-1082] Hierarchy block (/newMod1) cannot be directly upgraded.   
Please dive into the hierarchy and select individual cells to upgrade.
Note: A warning message is returned for the user-defined hierarchical module.