The following table shows the difference in
LOOKUP_INTERFACE_FREQ for SINGLE_CLOCK and DUAL_CLOCK modes.
| TDM Factor | LOOKUP RATE [Msps] | LOOKUP INTERFACE FREQ [MHz] | RAM CLOCK [MHz] | CLOCKING MODE |
|---|---|---|---|---|
| 4 | Up to 150 | Minimum 4xLOOKUP_RATE | LOOKUP_IF_FREQ | SINGLE CLOCK |
| 4 | Up to 150 | Minimum LOOKUP_RATE | Minimum 4xLOOKUP_RATE | DUAL CLOCK |
| 2 | Up to 300 | Minimum 2xLOOKUP_RATE | LOOKUP_IF_FREQ | SINGLE CLOCK |
| 2 | Up to 300 | Minimum 2xLOOKUP_RATE | Minimum 2xLOOKUP_RATE | DUAL CLOCK |
| 1 | Up to 600 | LOOKUP_IF_FREQ | LOOKUP_IF_FREQ | SINGLE CLOCK |
Note: Dual clock mode is
recommended for Lookup rates up to 300 Mlps.