This module accepts transmitter data from the GMII-style interface from the
attached client MAC/External PHY, and samples the input data on the 125 MHz reference
clock, clk125m. This sampled data can then be connected
directly to the input GMII of the 1G/2.5G Ethernet PCS/PMA or SGMII netlist. The 1 Gbps
and 100 Mbps cases are shown in the following figure.
At all speeds, the client MAC/External PHY logic should drive the GMII transmitter data
synchronously to the rising edge of the 125 MHz reference clock while using the
sgmii_clk_en signal (derived from the Clock Generation module) as a
clock enable. The frequency of this clock enable signal ensures the correct data rate
and correct data sampling between the two devices.