To minimize consumption of routing resources, the various clock and data signals take on different functions depending on the configured MRMAC operating mode. The following table details the meaning of the various clock and data signals for the given MRMAC configuration settings. For FEC only modes, data/clocks are shared with the transceiver interface.

Table 1. Transceiver Signaling
MRMAC Configuration Active MRMAC Port Number of Active GT Lanes Active GT Clocks Active GT Interface Data Bus
10/25GE

Narrow SerDes

0 1 rx_serdes_clk[0] rx_serdes_data0[39:0]
tx_core_clk[0] tx_serdes_data0[39:0]
1 1 rx_serdes_clk[1] rx_serdes_data1[39:0]
tx_core_clk[1] tx_serdes_data1[39:0]
2 1 rx_serdes_clk[2] rx_serdes_data2[39:0]
tx_core_clk[2] tx_serdes_data2[39:0]
3 1 rx_serdes_clk[3] rx_serdes_data3[39:0]
tx_core_clk[3] tx_serdes_data3[39:0]
10/25GE

Wide SerDes

0 1 rx_serdes_clk[0]

rx_alt_serdes_clk[0]

rx_serdes_data0[79:0]

fec_rx_din_start_0

tx_core_clk[0]

tx_alt_serdes_clk[0]

tx_serdes_data0[79:0]

fec_tx_dout_start_0

1 1 rx_serdes_clk[1]

rx_alt_serdes_clk[1]

rx_serdes_data1[79:0]

fec_rx_din_start_1

tx_core_clk[1]

tx_alt_serdes_clk[1]

tx_serdes_data1[79:0]

fec_tx_dout_start_1

2 1 rx_serdes_clk[2]

rx_alt_serdes_clk[2]

rx_serdes_data2[79:0]

fec_rx_din_start_2

tx_core_clk[2]

tx_alt_serdes_clk[2]

tx_serdes_data2[79:0]

fec_tx_dout_start_2

3 1 rx_serdes_clk[3]

rx_alt_serdes_clk[3]

rx_serdes_data3[79:0]

fec_rx_din_start_3

tx_core_clk[3]

tx_alt_serdes_clk[3]

tx_serdes_data3[79:0]

fec_tx_dout_start_3

40GE

Narrow SerDes

0 4 rx_serdes_clk[0]

rx_serdes_clk[1]

rx_serdes_clk[2]

rx_serdes_clk[3]

rx_serdes_data0[15:0]

rx_serdes_data1[15:0]

rx_serdes_data2[15:0]

rx_serdes_data3[15:0]

tx_core_clk[0] tx_serdes_data0[15:0]

tx_serdes_data1[15:0]

tx_serdes_data2[15:0]

tx_serdes_data3[15:0]
40GE

Wide SerDes

0 4 rx_serdes_clk[0]

rx_serdes_clk[1]

rx_serdes_clk[2]

rx_serdes_clk[3]

rx_alt_serdes_clk[0]

rx_alt_serdes_clk[1]

rx_alt_serdes_clk[2]

rx_alt_serdes_clk[3]

rx_serdes_data0[32:0]

rx_serdes_data1[32:0]

rx_serdes_data2[32:0]

rx_serdes_data3[32:0]

tx_core_clk[0]

tx_alt_serdes_clk[0]

tx_alt_serdes_clk[1]

tx_alt_serdes_clk[2]

tx_serdes_data0[32:0]

tx_serdes_data1[32:0]

tx_serdes_data2[32:0]

tx_serdes_data3[32:0]

50GE

Narrow SerDes

0 1 rx_serdes_clk[0] rx_serdes_data0[39:0]
tx_core_clk[0] tx_serdes_data0[39:0]
2 rx_serdes_clk[1] rx_serdes_data1[39:0]
N/A tx_serdes_data1[39:0]
2 1 rx_serdes_clk[2] rx_serdes_data2[39:0]
tx_core_clk[2] tx_serdes_data2[39:0]
2 rx_serdes_clk[3] rx_serdes_data3[39:0]
N/A tx_serdes_data3[39:0]
50GE

Wide SerDes

0 2 rx_serdes_clk[0]

rx_alt_serdes_clk[0]

rx_serdes_data0[79:0]

fec_rx_din_start_0

tx_core_clk[0]

tx_alt_serdes_clk[0]

tx_serdes_data0[79:0]

fec_tx_dout_start_0

2 2 rx_serdes_clk[2]

rx_alt_serdes_clk[2]

rx_serdes_data2[79:0]

fec_rx_din_start_2

tx_core_clk[2]

tx_alt_serdes_clk[2]

tx_serdes_data2[79:0]

fec_tx_dout_start_2

100GE

Narrow SerDes

0 4 rx_serdes_clk[0]

rx_serdes_clk[1]

rx_serdes_clk[2]

rx_serdes_clk[3]

rx_serdes_data0[39:0]

rx_serdes_data1[39:0]

rx_serdes_data2[39:0]

rx_serdes_data3[39:0]

tx_core_clk[0] tx_serdes_data0[39:0]

tx_serdes_data1[39:0]

tx_serdes_data2[39:0]

tx_serdes_data3[39:0]

100GE

Wide SerDes

0 4 rx_serdes_clk[0]

rx_serdes_clk[1]

rx_serdes_clk[2]

rx_serdes_clk[3]

rx_serdes_data0[79:0]

rx_serdes_data1[79:0]

rx_serdes_data2[79:0]

rx_serdes_data3[79:0]

tx_core_clk[0]

tx_alt_serdes_clk[0]

tx_serdes_data0[79:0]

tx_serdes_data1[79:0]

tx_serdes_data2[79:0]

tx_serdes_data3[79:0]

  1. The fec_tx_dout_start and fec_rx_din_start are only used in the FEC only modes and clocked by alt_serdes_clk.
Important: The design must meet the following rules when connecting the Versal MRMAC Hard IP core to the transceivers:
  1. GTs have to be contiguous.
  2. For MRMAC operating in wide SerDes mode (CTL_SERDES_WIDTH_[0..3]<2> == 1), the MRMAC and connected GTYE5_QUAD instance should be placed within the same Clock Region.
  3. For MRMAC operating in narrow SerDes mode (CTL_SERDES_WIDTH_[0..3]<2> == 0), the MRMAC and connected GTYE5_QUAD instance should be placed either within the same Clock Region, or one horizontal Clock Regions above or below the MRMAC instance.
  4. MRMAC 100GE, 40GE mode should use four contiguous GTYs and 50GE should use two contiguous GTYs from the same GTYE5_QUAD.
Note: MRMAC and GTYE5_QUAD placed in horizontally opposite locations are not recommended. However for extreme cases, you can try to use them by adding pipeline registers between MRMAC an GTY to ease the timing.