Lookup Interface Ports - 1.0 English - PG427

Cached DRAM Binary CAM LogiCORE IP Product Guide (PG427)

Document ID
PG427
Release Date
2023-10-18
Version
1.0 English

CDBCAM supports standard AXI4-Stream interface for lookup request and response functionality. The interface supported parameters values are:

Table 1. Lookup Interface Parameters
Local Parameter Width Description
S_LI_WIDTH


Width of input key data bus
M_LI_WIDTH

Width of output response data bus
Table 2. Lookup Interface
Port Name I/O Width Clock Description
key_clk I 1 The key clock is used for the lookup and memory interfaces.
rstn I 1 Asynchronous reset (active_low). The reset input is synchronized internally to key_clk domain.
s_axis_lkup_tdata I S_LI_WIDTH key_clk The Lookup Request key. Tdata is padded with zeros (if necessary) to S_LI_WIDTH bits length.
s_axis_lkup_tready O 1 key_clk The Lookup Request ready. Tready indicates that the core is ready to accept lookup requests.
s_axis_lkup_tvalid I 1 key_clk The Lookup Request valid. Tvalid indicates that the lookup request key is valid. A lookup is initiated when both tready and tvalid are high for one clock cycle.
m_axis_lkup_tdata O M_LI_WIDTH key_clk The response value associated with the matching entry.
m_axis_lkup_tready I 1 key_clk The Lookup Response ready.
m_axis_lkup_tvalid O 1 key_clk The Lookup Response valid.
dbiterr O 1 key_clk BCS double-bit error output status. A double-bit error has been detected by the ECC scrubbing mechanism. The outputs are not triggered by lookup operations, only activated when the ECC scrubber runs every 1 ms.